optris::sdk::SignalValue
One observation. valid == false means the producer did not produce a value this cycle; a rule on it goes kOrphaned rather than silently holding its last state.
value is in the unit of the quantity the signal carries. A temperature (a region's minimum, maximum, mean, median or percentile, a camera probe, the scene extremes, a PIF channel whose own unit is a temperature) is in the SDK's temperature unit (Celsius unless SetTemperatureUnit() chose Fahrenheit), and a region's standard deviation is a difference in degrees of that unit. A coverage, area, count, coordinate or PIF voltage is not converted, and an application signal is in whatever unit the application published it in.
Public attributes
value
double value = 0.0
the observation itself
valid
bool valid = false
false when nothing was produced this cycle
timestamp_us
uint64_t timestamp_us = 0
when it was observed, in microseconds
sequence
uint64_t sequence = 0
Increments once per publication, so a consumer can tell a repeated value from a stalled producer.