The limits one band is evaluated against.
In the unit of the quantity the rule's input carries. For a temperature input low and high are temperatures in the SDK's temperature unit (Celsius unless optris_sdk_set_temperature_unit() chose Fahrenheit), and hysteresis, delta and epsilon are differences in degrees of that unit (kelvin-sized in Celsius, Fahrenheit-sized in Fahrenheit). For a rule with a reference (optris_sdk_rule_set_reference()) the input is an offset, so all five are differences. A coverage, an area, a coordinate or a PIF voltage is not converted. The SDK keeps a limit in Celsius, so one set before a unit switch keeps its meaning and reads back in the new unit.
Public attributes
struct_size
uint32_t struct_size
Set to sizeof(optris_sdk_limits).
low
float low
Lower limit, in the signal's own unit (see above).
high
float high
Upper limit, in the signal's own unit (see above).
hysteresis
float hysteresis
Release deadband. The value must come back this far past the limit before the band drops, which is what stops an alarm chattering on a value sitting exactly on its threshold.
delta
float delta
OPTRIS_SDK_COMPARE_CHANGED only: the smallest change that counts as a change.
epsilon
float epsilon
OPTRIS_SDK_COMPARE_EQUAL only: the tolerance around high.