EmissivityConversionSupport

public enum EmissivityConversionSupport

Whether a source can re-evaluate a reading at another emissivity.

Read this before you offer the control, the same way ReferenceCorrectionSupport is read. Until this existed the capability was undiscoverable, and it depended on something no application can predict: whether the camera had landed on the GPU pipeline, which the SDK chooses per camera (by resolution, by the mode it was opened in, by its calibration type and by whether a GPU was usable), and can change mid-session.

A reason rather than a boolean, because the negatives are not equivalent to whoever has to act on them. A camera that has not loaded its calibration yet will be able to do this shortly; a sample-point camera never will; a recording that carries no characteristic curve cannot, and a newer recording of the same camera can.

This enum is : int to match the C ABI. New members may be appended by a future SDK, so a switch over it should have a default arm.

Value
Unknown 0 Nobody has looked yet: the camera is not open. Never treat this as support. It is the value a fresh object carries, so any classification that admits it admits every camera nobody asked.
Supported 1 This source can convert. There is an invertible characteristic curve behind it, whichever pipeline it runs and whether it is a camera, a recording or a reopened snapshot.
NoEnergyCurve 2 There is no characteristic curve here: a sample-point camera (the PI 1M family, whose radiometry lives in its calibration data rather than in a curve), a camera whose calibration has not loaded, or a file written before recordings carried their camera's table.
CurveNotInvertible 3 A curve is present and its table is not non-decreasing, so every lookup would answer with one entry. A broken calibration file rather than a camera property, and something somebody can replace.