OptrisOptrisDocumentation

Documentation/OTC SDK/Optris.Sdk — C# API referencev12.0

ShutterCorrectionOutcome

public enum ShutterCorrectionOutcome

What a closure the SDK did not command did to the dark reference.

Only a process interface can make such a closure: an input configured as PifChannelKind.FlagControl, Shutter Control, hands the camera's flag to the wire, and every closure the wire makes is a chance to correct.

A different question from ShutterState.Error. That means the shutter was commanded and did not take the position asked of it. A closure too short to average a reference from is a shutter that moved exactly as it was told, in a break the production line made brief.

Value
Applied 0 Enough frames. A new dark reference is in force from the frames that follow the closure.
SkippedTooShort 1 Fewer frames than ShutterCorrection.FramesRequired, and there was a reference to keep, so it was kept.
AppliedWithoutAReferenceToKeep 2 Fewer frames than required, and there was no reference at all, so this one was used anyway.