OptrisOptrisDocumentation

Documentation/OTC SDK/optris_sdk — Python API referencev12.0

PifChannelConfig

class optris_sdk.pif.PifChannelConfig

What one channel is for.

A digital input is a level with a threshold, not a bit, which is why threshold lives here rather than in a global setting.

A channel whose value is a temperature (KIND_AMBIENT_TEMPERATURE, KIND_INTERNAL_TEMPERATURE, and a measurement field of a temperature statistic) has the SDK's temperature unit as its own: Celsius unless optris_sdk.set_temperature_unit chose Fahrenheit. Its gain and offset map that unit to the wire, so in Fahrenheit they read re-expressed (gain divided by 1.8, the offset shifted to match) and still drive the same wire value; its threshold and its clamp are temperatures, except that 0 and 0 stays "no clamp" in either unit. On every other channel nothing here is converted.

What is on the wire is never converted. The value Pif.write_analog_output takes and the value Pif.read_analog_input decodes follow the unit on such a channel; the level on the pin does not, because a wire value is never a temperature. Pif.read_analog_output, Pif.read_raw_analog_input, a snapshot's analog_outputs and raw_analog_inputs, and the FIELD_ANALOG_OUT signal answer in volts or milliamperes, the same numbers in Celsius and in Fahrenheit.

  • Parameter index — which channel of its kind.
  • Parameter direction — DIRECTION_INPUT or DIRECTION_OUTPUT.
  • Parameter signal — SIGNAL_DIGITAL, SIGNAL_ANALOG or SIGNAL_FAIL_SAFE.
  • Parameter kind — what the value means -- KIND_EMISSIVITY, KIND_FLAG_CONTROL and the rest.
  • Parameter input_min — the low end of the clamp on a decoded analog input, in the channel's own unit. Leave both at 0 for no clamp.
  • Parameter input_max — the high end of that clamp.
  • Parameter gain — multiplies the electrical value to reach the value range it stands for.
  • Parameter threshold — for a digital input, the level that counts as high.

PifChannelConfig — properties

index

Which channel of its kind.

direction

DIRECTION_INPUT or DIRECTION_OUTPUT.

signal

SIGNAL_DIGITAL, SIGNAL_ANALOG or SIGNAL_FAIL_SAFE.

kind

What the value means. See channel_kind_name.

kind_name

gain

Multiplies the electrical value to reach the value range it stands for. On a temperature channel it maps the SDK's temperature unit, so it reads re-expressed in Fahrenheit (see the class docstring).

offset

Added after gain.

input_min

The low end of the clamp on a decoded analog input, in the channel's own unit (a temperature in the SDK's temperature unit on a temperature channel). 0 here and in input_max means no clamp.

input_max

The high end of that clamp, in the same unit.

threshold

For a digital input, the level that counts as high. In the channel's own unit, so a temperature in the SDK's temperature unit on a temperature channel.

threshold_low_active

Whether the low side of threshold is the active one.

active_low

Whether this line is active when it is low.

autonomous

Whether the camera firmware drives this channel itself.

active_value

Level driven when the channel's condition holds.

inactive_value

Level driven when it does not.

intermediate_value

Level driven while neither applies.

output_range

The range an analog output works in, as an AnalogRange.

decimals

How many decimals a value on this channel is rendered to.

name

The channel's own name, or ''.

unit

The unit the decoded value is in, or ''.

PifChannelConfig — methods

__repr__()