OptrisOptrisDocumentation

Documentation/OTC SDK/optris_sdk — Rust API referencev12.0

rule — functions and constants

Alarm rules: one signal, one condition, and what to do about it.

A measuring area's over-temperature alarm, an alarm on a process interface input and an alarm on a value your own application publishes are three values of the same shape. Build a Rule, set its input and condition, add actions, then hand it to crate::Camera::add_rule, which copies it.

Rules are evaluated once per frame on the frame thread. Actions run on a separate thread, so a slow action never holds up the camera.

pub const NO_MIN_INTERVAL_MS: u32 = sys::OPTRIS_SDK_SNAPSHOT_NO_MIN_INTERVAL;

OPTRIS_SDK_SNAPSHOT_NO_MIN_INTERVAL: a snapshot action's min_interval_ms meaning no rate limit at all.

The field has three states on the ABI: 0 is the SDK default of one second, this is none, and anything else is the interval itself. See sdk_c.h for why "none" is not 0 there when it is in C++ and in RuleActionKind::Snapshot::min_interval.