OptrisOptrisDocumentation

Documentation/OTC SDK/Optris.Sdk — C# API referencev12.0

AlarmLimits

public readonly record struct AlarmLimits : IEquatable<AlarmLimits>

The limits one alarm band is evaluated against.

In the unit of the quantity the rule's input carries. For a temperature input AlarmLimits.Low and AlarmLimits.High are temperatures in the SDK's temperature unit (Celsius unless Sdk.TemperatureUnit chose Fahrenheit), and AlarmLimits.Hysteresis, AlarmLimits.Delta and AlarmLimits.Epsilon are differences in degrees of that unit (kelvin-sized in Celsius, Fahrenheit-sized in Fahrenheit). For a rule with an AlarmRule.Reference the input is an offset, so all five are differences. A coverage, an area, a count or a process-interface voltage is not converted. The SDK keeps a limit in Celsius, so one set before a unit switch keeps its meaning and reads back in the new unit.

AlarmLimits: properties

public float Delta { get; init; }

For AlarmCompare.Changed: the smallest change that counts as one.

public float Epsilon { get; init; }

For AlarmCompare.Equal: the tolerance around AlarmLimits.High.

public float High { get; init; }

The upper limit, in the signal's own unit.

public float Hysteresis { get; init; }

The release deadband. The value has to come back this far past the limit before the band drops.

This is what stops an alarm chattering on a value sitting exactly on its threshold. A few tenths of a degree is usually enough; zero means the alarm follows every crossing. On a temperature, a difference in degrees of the SDK's temperature unit.

public float Low { get; init; }

The lower limit, in the signal's own unit.