public enum FailSafeHealth

What the fail-safe line is actually doing, as opposed to what was configured.

FailSafeHealth.Beating is the only value that says the signal is reaching the interface fast enough to keep its relay energised. The SDK's log line about the heartbeat running is about the watchdog (whether frames are arriving and the pipeline is finishing them), which is a true statement that says nothing about the wire.

Value
Disabled 0 No fail-safe is configured. Not a fault.
Arming 1 Armed, and no heartbeat has arrived yet. Nothing has retriggered the relay, so anything wired to the fail-safe terminals is reading a fault, correctly, because the camera is not yet known to be delivering frames.
Beating 2 Edges are arriving inside the interface's budget. The relay is being retriggered and is held.
Late 3 Armed, and the line has not moved for longer than the relay can hold -- or has never moved since it was armed that long ago, or the camera reports that it cannot reach the Stackable PIF the line is on. The relay has released.