alarms — functions
Rules over signals, and the one model behind all of them.
An alarm is a Rule: one signal, one Condition, and
what to do about it. That is the whole model, and it is the same model
whether the signal is a region's maximum temperature, the camera's own
chip temperature, or a PIF input -- only SignalId differs.
Everything that used to be spread across three unrelated mechanisms --
the warning band, the hysteresis dead-band, the delay in frames,
latching -- is on the condition.
Attaching a rule to a region
camera.alarms.add(rule, region_id=...) fills the rule's signal
slot in from the region id, so the index on a region-domain
SignalId is discarded and should be left at zero. Passing a
"real" number there reads as if it identified the region, and it does
not -- a signal slot is not a region id.
camera.alarms.add(rule) with no region does no such filling in, and
there the slot has to be right. That form is for a rule on the device
itself, where there is no region to take it from.
What an event carries
An AlarmEvent carries its own cause: which region, which
rule, which limit, and the value that crossed it. Only a transition
that actually crossed something carries a limit, though: settling to
ALARM_CLEAR on the first frame reports limit_kind == LIMIT_NONE with limit left at zero (NaN in Fahrenheit), and
printing that zero as if it were a threshold is how "(limit 0.0)" ends
up on every line of a log. Check AlarmEvent.has_limit first.
Units
A limit, a hysteresis and an event's value are in the unit of the
signal the rule watches. For a temperature (a region's minimum,
maximum, mean, median or percentile, the camera's probe temperatures,
the scene's extremes) that is the SDK's temperature unit: Celsius
unless optris_sdk.set_temperature_unit chose Fahrenheit. A
hysteresis, a delta, a region's standard deviation and every limit of
a rule with a reference (which are offsets) are temperature
differences, in degrees of that unit with no offset: 2 K is 3.6 F. A
PIF channel is in its own unit, which follows the SDK's only for a
channel whose kind is a temperature. A coverage, an area, a count and
a value the application publishes itself are never converted.
The callback fires on the SDK's action thread, never on the frame
thread -- but it is still an SDK thread, so every rule in
optris_sdk.callbacks applies.
limit_kind_name(kind)
Which limit a transition crossed, spelled out.
action_outcome_name(outcome)
What became of an alarm action, in words.
state_name(state)
An alarm state, spelled out rather than as an ordinal.