class optris_sdk.alarms.SignalId

Which observation a rule watches.

Addressed rather than named, so a rule on a region's mean temperature, on the camera's chip temperature and on a PIF input are the same shape.

SignalId — properties

domain

Which family of signals: DOMAIN_REGION and friends.

field

Which value within that family: FIELD_MAX and friends.

index

The region slot, PIF channel or user slot, as applicable.

SignalId — methods

__repr__()

region(cls, field)

A region's statistic.

No index: camera.alarms.add(rule, region_id=...) fills the slot in from the region it attaches the rule to, and a number passed here would be discarded. A signal slot is not a region id, and writing one as though it were is the mistake this constructor removes the opportunity for.

device(cls, field)

Something the camera reports about itself.

pif(cls, field, channel)

A PIF channel.

user(cls, slot)

A value the application publishes itself.

slot is what Alarms.register_signal returned. There is no field to choose: a published value is the whole of the signal, so the field is fixed at FIELD_VALUE.

That field is 400 and not 0, and it is why this constructor exists rather than leaving a caller to build the id. A user signal addressed with field 0 reads as a region's minimum, matches nothing in the user domain, and Alarms.read_signal then reports it as having no value -- which is indistinguishable from a signal nobody has published to yet.