class optris_sdk.control.RadiationSources
Which radiation parameters a process-interface input is driving.
Returned by Radiometry.sources and by
optris_sdk.camera.Camera.radiation_sources.
Radiometry.get reads the parameters back from the engine
rather than echoing the last write, so a value a PIF input supplied
comes back from it looking exactly like one that was set through
this API. This is what tells them apart: an application that lets
an operator edit the emissivity or the ambient temperature can show
the field read-only, and say which input owns it, instead of
accepting an edit the next PIF sample discards.
The answer follows the channel table, not the samples, so reading it once after configuring the process interface is enough.
Only the two parameters a PIF can drive are here. There is no
transmissivity, because no PIF channel kind decodes to one; a field
fixed at optris_sdk.RADIATION_SOURCE_SDK that could never
hold anything else is not information.
- Attribute
emissivity—optris_sdk.RADIATION_SOURCE_SDKoroptris_sdk.RADIATION_SOURCE_PIF. - Attribute
ambient_temp— the same, for the ambient temperature. A PIF ambient channel takes effect regardless ofestimate_ambientand clears it as a side effect, so a configuration that asked the camera to estimate the ambient quietly stops doing so once such a channel is configured. This says the channel is driving it; it does not say what happened to the estimate flag -- read that back withRadiometry.get.