Radiometry
class optris_sdk.control.Radiometry
Making the numbers true: camera.radiometry.
Radiometry — properties
effective_ambient_c
The ambient the pipeline is actually using, or None.
In the SDK's temperature unit (Celsius unless
optris_sdk.set_temperature_unit chose Fahrenheit).
None means there is no ambient in force yet -- before the
first frame the housing probe has not been read, so there is
no estimate to report. It is None rather than a number
because every number is a temperature, and a caller that shows
this value could not tell "not known yet" from "0 C".
This used to return (temperature_c, estimated). The second
element was the C call's validity flag under the wrong name:
it read True after streaming with estimate_ambient off,
contradicting the setting it claimed to describe. Whether the
value is estimated is self.get().estimate_ambient; this
property answers only what is in force.
Radiometry — methods
get()
The radiation parameters as the camera holds them.
set(config)
Apply a whole radiation record.
Every field is written. Read one with get and change
what you mean to change rather than building a fresh record,
which would write defaults over the rest.
sources()
Which of the two parameters a PIF input is driving.
A RadiationSources. See it for when the answer changes
-- with the channel table, not with each sample.
- Raises
~optris_sdk.errors.NotSupportedError— on a replay or a still. Neither has a process interface, so there is no question to answer about them.