RaviInfo
class optris_sdk.ravi.RaviInfo(NamedTuple)
What a .ravi holds, read without converting it.
header_version is 0 for an unreadable file, and the fields after
it are then defaults. model is empty when the file does not name
the camera, which a header before version 1009 never does.
recorded_at_utc is ISO 8601 UTC, or empty when unknown: the
recording PC's clock reading placed in the time_zone given to
inspect, or else in this computer's zone, which is right only
if this computer is in the zone the recording PC was in.
inspect_start_time gives the clock reading itself.
range_min_c and range_max_c are the recorded temperature
range in the SDK's temperature unit (Celsius unless
optris_sdk.set_temperature_unit chose Fahrenheit).