OptrisOptrisDocumentation

Documentation/OTC SDK/Optris.Sdk — C# API referencev12.0

RaviInfo

public sealed class RaviInfo

What a PIX Connect recording holds, read without converting it.

Returned by Ravi.Inspect(…). When RaviInfo.Verdict is RaviVerdict.Unreadable only RaviInfo.Path, RaviInfo.Bytes and RaviInfo.Detail mean anything.

RaviInfo: properties

public ulong Bytes { get; }

File size in bytes.

public int ContainerGeneration { get; }

The container layout: 1 for the 2010-era one, 2 after.

public string Curve { get; }

"planck" or "normtable": which radiometric model the file uses. Empty when it has none.

public uint DeclaredFrames { get; }

Frames the file's headers declare for the whole recording: the OpenDML total where the file has one, else the video stream's length, else the main AVI header's count. Ravi.InspectFrameCounts(…) says which.

public string Detail { get; }

Why, when RaviInfo.Verdict is not RaviVerdict.Convertible. Empty otherwise.

public double Emissivity { get; }

Emissivity in force at the first frame.

public double FrameRate { get; }

Frames per second.

public bool HasVisibleChannel { get; }

Whether the file also carries a visible-light picture. An SDK recording is thermal only, so that picture is not converted.

public int HeaderVersion { get; }

PIX Connect's frame header version, 1001 to 1013. Zero when the file is unreadable.

public uint Height { get; }

Picture height in pixels.

public string Model { get; }

The camera model, as the SDK names a live camera ("PI 640i", "Xi 80"). Empty when the file does not say: a header before version 1009 carries no hardware revision, and the serial alone does not name a model.

public string Path { get; }

The path as given.

public double RangeMaxC { get; }

High end of the camera's calibrated range, in the SDK's temperature unit.

public double RangeMinC { get; }

Low end of the camera's calibrated range, in the SDK's temperature unit (Celsius unless Sdk.TemperatureUnit chose Fahrenheit), whatever the C in the name says. The file states Celsius; this is converted as it is read.

public Nullable<DateTimeOffset> RecordedAtUtc { get; }

When the recording started, UTC, to the second, or null when the file does not say.

A .ravi stores its start as the recording PC's local clock, with no time zone. This is that clock reading placed in the zone given to Ravi.InspectInZone(…), or else in this computer's zone, which is right only when this computer is in the zone the recording PC was in. Ravi.InspectStartTime(…) gives the clock reading itself.

public int Serial { get; }

The camera's serial number.

public double Transmissivity { get; }

Transmissivity in force at the first frame.

public RaviVerdict Verdict { get; }

Whether, and how, the file converts.

public uint Width { get; }

Picture width in pixels.