ImportOptions
pub struct ImportOptions
How import converts. Built with ImportOptions::new and the
setters, so a later option can be added without breaking anyone.
let options = optris_sdk::ravi::ImportOptions::new()
.allow_short_wave(true)
.frame_limit(100);
ImportOptions — methods
pub fn new() -> Self
The defaults: the SDK's own normalization tables, no short-wave files, no clamping, every frame, the statistics scan on and the per-frame extras kept.
pub fn time_zone(mut self, zone: RaviTimeZone) -> Self
The zone the PC that recorded the file was in.
The recording always states a UTC start
(crate::Camera::playback_start_time_us) and a zone
(crate::Camera::playback_time_zone). Unset, this computer's
zone is used: the recording says it was assumed, the log warns,
and correct_start_time sets it right afterwards.
pub fn norm_directory(mut self, directory: &str) -> Self
Where Norm-<n>.prn is. Unset, the import uses the tables the
SDK ships, which is right unless you mean to use others.
pub fn allow_short_wave(mut self, allow: bool) -> Self
Convert a file whose verdict is RaviVerdict::ShortWave
anyway, on the linear axis. Off by default; see the verdict for
what is wrong then. A short-wave recording PIX Connect's split
axis is built for converts without it.
pub fn clamp_to_range(mut self, clamp: bool) -> Self
Clamp temperatures to the camera's range plus 26 K either side, as PIX Connect does when it plays the file.
pub fn frame_limit(mut self, frames: u64) -> Self
Convert only the first frames frames. Zero, the default,
converts all of them.
pub fn scan(mut self, scan: bool) -> Self
Read the file once before converting it, for the scene's temperature range. On by default; off halves the work, and the recording then carries no scene range.
pub fn per_frame_extras(mut self, keep: bool) -> Self
Keep each frame's PIX Connect extras -- the five-state shutter flag, NMEA position, process interface readings -- in the frame records. On by default.